[Bugfix][Wan2.2] Apply UniPC flow shift once (#7576)

Signed-off-by: HAAZZZEEEE <wang-taicheng@qq.com>
This commit is contained in:
HAAZZZEEEE authored and GitHub committed 2026-09-16 10:06:41 +08:00
1 parent 2185c4e26f
commit 3eb5c3b4e6
11 files changed
+298 -34

No files matched your search

@@ -59,9 +59,11 @@ FASTWAN_DMD_SCHEDULER_SHIFT = 8.0
def build_wan_scheduler(sample_solver: str, flow_shift: float) -> Any:
if sample_solver == "unipc":
# Keep native Wan's unshifted training endpoints; set_timesteps applies
# the requested shift to the interpolated inference sigmas.
return FlowUniPCMultistepScheduler(
num_train_timesteps=1000,
shift=flow_shift,
shift=1.0,
prediction_type="flow_prediction",
)
if sample_solver == "euler":
@@ -774,7 +776,10 @@ class Wan22Pipeline(
self._sample_solver = sample_solver
self._flow_shift = flow_shift
self.scheduler.set_timesteps(num_steps, device=device)
if sample_solver == "unipc":
self.scheduler.set_timesteps(num_steps, device=device, shift=flow_shift)
else:
self.scheduler.set_timesteps(num_steps, device=device)
timesteps = self.scheduler.timesteps
self._num_timesteps = len(timesteps)
boundary_timestep = None